Sign In | Join Free | My himfr.com
Home > Mineral Insulated Heating Cable >

MgO Insulation Heating Cable For Accurate Temperature Measurement With NiCr-NiS Conductor

Ningbo Leadkin Instrument Complete Sets of Equipment Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap MgO Insulation Heating Cable For Accurate Temperature Measurement With NiCr-NiS Conductor from wholesalers
     
    Buy cheap MgO Insulation Heating Cable For Accurate Temperature Measurement With NiCr-NiS Conductor from wholesalers
    • Buy cheap MgO Insulation Heating Cable For Accurate Temperature Measurement With NiCr-NiS Conductor from wholesalers
    • Buy cheap MgO Insulation Heating Cable For Accurate Temperature Measurement With NiCr-NiS Conductor from wholesalers

    MgO Insulation Heating Cable For Accurate Temperature Measurement With NiCr-NiS Conductor

    Ask Lasest Price
    Brand Name : LEADKIN
    Model Number : LK-K
    Certification : ISO9001, IATF16949, CE
    Price : USD 0.35-6.8/M
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 1,000,000M/year
    Delivery Time : 2-7 working days
    • Product Details
    • Company Profile

    MgO Insulation Heating Cable For Accurate Temperature Measurement With NiCr-NiS Conductor

    Quick Details:

    Type: K/N/E/J/T/S/R/B

    Place of Origin: Zhejiang, China (Mainland)

    Accuracy: I-0.4%t, II-0.75%t, III-1.5%t

    Core number: Single / Double

    Insulator: 99.6% high purity MgO

    Certificate:ISO9001, IATF16949, CE

    Application: connecting with thermocouple and instrument machine

    Conductor material: NiCr-NiSi, NiCrSi-NiSi, NiCr-Konstantan, Fe-Konstantan, Cu-Konstantan

    Sheath material: Inconel600, 0Cr18Ni10Ti, SS304S,SS316L, SS310,SS316,GH3030, GH3039, GH747

    Sheath Dia(mm): 0.5mm to 12.7mm :φ0.5,φ1.0, φ1.5(1.6), φ2.0, φ3.0(3.2),φ4.0,φ5.0(4.8),φ6.0(6.4),φ8.0,φ12.7


    Type for Sheath Wire Type K:

    Product NameCodeTypeShaeth MaterialOutside Dia.Temperature
    NiCr-NiSi /NiCr-NiAlKKKSS304 SS3160.5-1.0400
    1.5-3.2600
    4.0-8.0800
    SS310 Inconel6000.5-1.0500
    1.5-3.2800
    4.0-6.4900
    8.0-12.71000
    NiCrSi-NiSiNKNSS304 SS3160.5-1.0400
    1.5-3.2600
    4.0-8.0800
    SS310 Inconel6000.5-1.0500
    1.5-3.2800
    4.0-6.4900
    8.0-12.71000
    NiCr-KonstantanEKESS304 SS3160.5-1.0400
    1.5-3.2600
    4.0-8.0800
    Fe-KonstantanJKJSS304 SS3160.5-1.0400
    1.5-3.2600
    4.0-8.0800
    Cu-KonstantanTKTSS304 SS3160.5-1.0400
    1.5-3.2600
    4.0-8.0800
    RhPt10-PhSKSInconel6006.0-12.71100

    Different temperature measuring media and service conditions have an impact on the service life and temperature range of armored thermocouples, the data in the table is only recommended data.


    Accuracy for Sheath Wire Type K

    TypeClass IClass II
    AccuracyTemp.RangeAccuracyTemp.Range
    K±1.5℃-40~375℃±2.5℃-40~375℃
    ±0.4%375℃-1000℃±0.75%375℃-1000℃
    N±1.5℃-40~375℃±2.5℃-40~375℃
    ±0.4%375℃-1000℃±0.75%375℃-1000℃
    E±1.5℃-40~375℃±2.5℃-40~375℃
    ±0.4%375℃-800℃±0.75%375℃-800℃
    J±1.5℃-40~375℃±2.5℃-40~375℃
    ±0.4%375℃-800℃±0.75%375℃-800℃
    T±0.5℃-40~125℃±1.0℃-40~125℃
    ±0.4%125℃-350℃±0.75%125℃-350℃
    S0-1100℃±1.0℃0-1100℃±1.5℃

    About this product:


    Type N:

    This designation usually refers to a specific type of thermocouple or may indicate a specific application or standard related to the heating cable. It's important to verify the exact meaning depending on the context of your project.

    Applications:

    Industrial Heating: Used in applications requiring temperature maintenance, such as pipelines, vessels, and tanks.

    Freeze Protection: Often employed in outdoor settings to prevent freezing of pipes and other equipment.

    Process Heating: Used in various manufacturing processes that require controlled heating.

    Considerations:

    Voltage and Power Rating: Ensure that the heating cable is rated for the voltage and power requirements of your specific application.

    Installation Environment: Confirm that the materials used can withstand the environmental conditions (temperature, chemicals, moisture, etc.) of the intended installation site.

    Regulatory Compliance: Ensure compliance with relevant safety standards and regulations for electrical heating systems.


    Installation Questions:

    What is the recommended installation method for this type of heating cable?

    Ensure proper installation techniques are followed, including securing the cable and avoiding sharp bends that could damage the insulation.

    What are the necessary safety precautions during installation?

    Consider electrical safety measures, such as ensuring the power is switched off during installation and using appropriate personal protective equipment (PPE).

    What are the guidelines for connecting the heating cable to the power source?

    Understand the connection requirements, including the type of connectors and terminals that should be used to ensure a secure and reliable connection.

    Are there specific temperature limits for installation?

    Review the manufacturer's specifications regarding ambient temperature limits during installation to ensure optimal performance.

    Applications :

    • Solid waste incinerators
    • Sintering powdered metals
    • Firing ceramic materials
    • Gas or oil fired furnaces
    • Fuel fired heat exchangers
    • Box furnaces
    • Nuclear or hydrocarbon based energy plants
    • And many more...

    Product Pictures

    MgO Insulation Heating Cable For Accurate Temperature Measurement With NiCr-NiS Conductor


    Company Information:

    A. Main Products


    MgO Insulation Heating Cable For Accurate Temperature Measurement With NiCr-NiS Conductor


    B. Package


    We add heat shrink tubing and plastic film to make sure high insulated resistance.

    Except marking notes, we also have pass card and test report for every coil cable.

    MgO Insulation Heating Cable For Accurate Temperature Measurement With NiCr-NiS Conductor


    C. Mi cable Production line

    We have high - quality professional products, as well as advanced product lines and equipments. All of the products comply with international quality standards and are greatly appreciated in a variety of different markets throughout the world.Along the increasing market demands, we continuously satisfy customers by updating products to improve prouduction systems, improve quality.


    MgO Insulation Heating Cable For Accurate Temperature Measurement With NiCr-NiS Conductor


    Order Notice:

    1. Accurate quotation.

    2. Confirm the price, trade term, lead time, payment term etc.

    3. LEADKIN sales send the Proforma Invoice with LEADKIN seal.

    4. Customer arranges the payment for deposit and sends us bank slip.

    5. Middle Production-send photos to show the production line which you can see your products in . Confirm the estimated delivery time again.

    6. End Production-Mass production products photos.

    7. Clients make payment for balance and LEADKIN ships the goods. Inform the tracking number and check the status for clients.

    8. The order is finished perfectly when you receive the goods and get satisfied with them .

    9. Feedback to LEADKIN about Quality , Service, Market Feedback & Suggestion. And we will do better .


    Quality MgO Insulation Heating Cable For Accurate Temperature Measurement With NiCr-NiS Conductor for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Ningbo Leadkin Instrument Complete Sets of Equipment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)