Sign In | Join Free | My himfr.com
Home > Mineral Insulated Thermocouple Cable >

Outside Dia 0.5-12.7mm Thermocouple Cable For Accurate Temperature Measurement

Ningbo Leadkin Instrument Complete Sets of Equipment Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Outside Dia 0.5-12.7mm Thermocouple Cable For Accurate Temperature Measurement from wholesalers
     
    Buy cheap Outside Dia 0.5-12.7mm Thermocouple Cable For Accurate Temperature Measurement from wholesalers
    • Buy cheap Outside Dia 0.5-12.7mm Thermocouple Cable For Accurate Temperature Measurement from wholesalers

    Outside Dia 0.5-12.7mm Thermocouple Cable For Accurate Temperature Measurement

    Ask Lasest Price
    Brand Name : LEADKIN
    Model Number : LK-K
    Certification : ISO9001, IATF16949, CE
    Price : USD 0.5-6.8/M
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 1,000,000M/year
    Delivery Time : 2-7 working days
    • Product Details
    • Company Profile

    Outside Dia 0.5-12.7mm Thermocouple Cable For Accurate Temperature Measurement

    Quick Details:

    Type: K/N/E/J/T/S/R/B

    Place of Origin: Zhejiang, China (Mainland)

    Accuracy: I-0.4%t, II-0.75%t, III-1.5%t

    Core number: Single / Double

    Insulator: 99.6% high purity MgO

    Certificate:ISO9001, IATF16949, CE

    Application: connecting with thermocouple and instrument machine

    Conductor material: NiCr-NiSi, NiCrSi-NiSi, NiCr-Konstantan, Fe-Konstantan, Cu-Konstantan

    Sheath material: Inconel600, 0Cr18Ni10Ti, SS304S,SS316L, SS310,SS316,GH3030, GH3039, GH747

    Sheath Dia(mm): 0.5mm to 12.7mm :φ0.5,φ1.0, φ1.5(1.6), φ2.0, φ3.0(3.2),φ4.0,φ5.0(4.8),φ6.0(6.4),φ8.0,φ12.7


    Type for Sheath Wire Type K:

    Product NameCodeTypeShaeth MaterialOutside Dia.Temperature
    NiCr-NiSi /NiCr-NiAlKKKSS304 SS3160.5-1.0400
    1.5-3.2600
    4.0-8.0800
    SS310 Inconel6000.5-1.0500
    1.5-3.2800
    4.0-6.4900
    8.0-12.71000
    NiCrSi-NiSiNKNSS304 SS3160.5-1.0400
    1.5-3.2600
    4.0-8.0800
    SS310 Inconel6000.5-1.0500
    1.5-3.2800
    4.0-6.4900
    8.0-12.71000
    NiCr-KonstantanEKESS304 SS3160.5-1.0400
    1.5-3.2600
    4.0-8.0800
    Fe-KonstantanJKJSS304 SS3160.5-1.0400
    1.5-3.2600
    4.0-8.0800
    Cu-KonstantanTKTSS304 SS3160.5-1.0400
    1.5-3.2600
    4.0-8.0800
    RhPt10-PhSKSInconel6006.0-12.71100

    Different temperature measuring media and service conditions have an impact on the service life and temperature range of armored thermocouples, the data in the table is only recommended data.


    Accuracy for Sheath Wire Type K

    TypeClass IClass II
    AccuracyTemp.RangeAccuracyTemp.Range
    K±1.5℃-40~375℃±2.5℃-40~375℃
    ±0.4%375℃-1000℃±0.75%375℃-1000℃
    N±1.5℃-40~375℃±2.5℃-40~375℃
    ±0.4%375℃-1000℃±0.75%375℃-1000℃
    E±1.5℃-40~375℃±2.5℃-40~375℃
    ±0.4%375℃-800℃±0.75%375℃-800℃
    J±1.5℃-40~375℃±2.5℃-40~375℃
    ±0.4%375℃-800℃±0.75%375℃-800℃
    T±0.5℃-40~125℃±1.0℃-40~125℃
    ±0.4%125℃-350℃±0.75%125℃-350℃
    S0-1100℃±1.0℃0-1100℃±1.5℃

    About this product:

    Thermocouple
    Composition: A thermocouple is a temperature sensor made of two dissimilar metal wires joined at one end (the measuring junction). The other end is connected to a measuring instrument.

    Working Principle: Based on the Seebeck effect, where a voltage is generated when there is a temperature difference between the two junctions of the metals.

    Types: Common types include:

    Type K (Chromel-Alumel): General-purpose, wide temperature range (-200°C to 1260°C).

    Type J (Iron-Constantan): Lower temperature range (-40°C to 750°C).

    Type T (Copper-Constantan): Cryogenic applications (-200°C to 350°C).

    Type R/S (Platinum-Rhodium): High-temperature applications (up to 1600°C).

    Type N (Nicrosil-Nisil): High stability and resistance to oxidation.

    Applications:

    Temperature measurement in industrial processes, furnaces, engines, and laboratories.

    Often paired with MI Cable for protection in harsh environments.

    MI Cable and Thermocouple Combination
    MI Cable is often used as the protective sheath for thermocouples, especially in high-temperature, high-pressure, or corrosive environments.

    The combination provides:

    Enhanced durability and longevity of the thermocouple.

    Accurate temperature measurement in extreme conditions.

    Protection against mechanical damage and environmental factors.


    Applications :

    • Solid waste incinerators
    • Sintering powdered metals
    • Firing ceramic materials
    • Gas or oil fired furnaces
    • Fuel fired heat exchangers
    • Box furnaces
    • Nuclear or hydrocarbon based energy plants
    • And many more...

    Product Pictures

    Outside Dia 0.5-12.7mm Thermocouple Cable For Accurate Temperature Measurement


    Company Information:

    A. Main Products


    Outside Dia 0.5-12.7mm Thermocouple Cable For Accurate Temperature MeasurementOutside Dia 0.5-12.7mm Thermocouple Cable For Accurate Temperature Measurement


    B. Package


    We add heat shrink tubing and plastic film to make sure high insulated resistance.

    Except marking notes, we also have pass card and test report for every coil cable.


    C. Mi cable Production line

    We have high - quality professional products, as well as advanced product lines and equipments. All of the products comply with international quality standards and are greatly appreciated in a variety of different markets throughout the world.Along the increasing market demands, we continuously satisfy customers by updating products to improve prouduction systems, improve quality.


    Key Considerations When Using MI Cable with Thermocouples
    Sheath Material: Choose a sheath material compatible with the environment (e.g., stainless steel for general use, Inconel for high temperatures).

    Insulation Resistance: Ensure proper insulation resistance to avoid signal leakage.

    Flexibility: MI Cable can be rigid or flexible, depending on the application.

    Termination: Proper termination and sealing are critical to prevent moisture ingress.

    Calibration: Thermocouples should be calibrated regularly for accurate measurements.

    Order Notice:

    1. Accurate quotation.

    2. Confirm the price, trade term, lead time, payment term etc.

    3. LEADKIN sales send the Proforma Invoice with LEADKIN seal.

    4. Customer arranges the payment for deposit and sends us bank slip.

    5. Middle Production-send photos to show the production line which you can see your products in . Confirm the estimated delivery time again.

    6. End Production-Mass production products photos.

    7. Clients make payment for balance and LEADKIN ships the goods. Inform the tracking number and check the status for clients.

    8. The order is finished perfectly when you receive the goods and get satisfied with them .

    9. Feedback to LEADKIN about Quality , Service, Market Feedback & Suggestion. And we will do better .


    Quality Outside Dia 0.5-12.7mm Thermocouple Cable For Accurate Temperature Measurement for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Ningbo Leadkin Instrument Complete Sets of Equipment Co., Ltd.
    *Subject:
    *Message: