Sign In | Join Free | My himfr.com
Home > Thermocouple Temperature Probe >

K/N/E/J/T/S/R/B Type Thermocouple Temperature Probe

Ningbo Leadkin Instrument Complete Sets of Equipment Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap K/N/E/J/T/S/R/B Type Thermocouple Temperature Probe from wholesalers
     
    Buy cheap K/N/E/J/T/S/R/B Type Thermocouple Temperature Probe from wholesalers
    • Buy cheap K/N/E/J/T/S/R/B Type Thermocouple Temperature Probe from wholesalers

    K/N/E/J/T/S/R/B Type Thermocouple Temperature Probe

    Ask Lasest Price
    Brand Name : LEADKIN
    Model Number : LK-K
    Certification : ISO9001, IATF16949, CE
    Price : negotiation
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 1,000,000M/year
    Delivery Time : 2-7 working days
    • Product Details
    • Company Profile

    K/N/E/J/T/S/R/B Type Thermocouple Temperature Probe

    Quick Details:

    Type: K/N/E/J/T/S/R/B

    Place of Origin: Zhejiang, China (Mainland)

    Accuracy: I-0.4%t, II-0.75%t, III-1.5%t

    Core number: 2,3,4,6

    Inorganic mineral insulating lead material: Ni, Cu

    Insulator: 99.6% high purity MgO

    Certificate:ISO9001, IATF16949, CE

    Application: connecting with thermocouple and instrument machine

    Sheath material: 0Cr18Ni10Ti, SS304S,SS316L,SS316, Cu

    Sheath Dia(mm): φ3.0, φ4.0, φ6.0, φ8.0


    Type for Sheath Wire Type K:

    Product NameCodeTypeShaeth MaterialOutside Dia.Temperature
    NiCr-NiSi /NiCr-NiAlKKKSS304 SS3160.5-1.0400
    1.5-3.2600
    4.0-8.0800
    SS310 Inconel6000.5-1.0500
    1.5-3.2800
    4.0-6.4900
    8.0-12.71000
    NiCrSi-NiSiNKNSS304 SS3160.5-1.0400
    1.5-3.2600
    4.0-8.0800
    SS310 Inconel6000.5-1.0500
    1.5-3.2800
    4.0-6.4900
    8.0-12.71000
    NiCr-KonstantanEKESS304 SS3160.5-1.0400
    1.5-3.2600
    4.0-8.0800
    Fe-KonstantanJKJSS304 SS3160.5-1.0400
    1.5-3.2600
    4.0-8.0800
    Cu-KonstantanTKTSS304 SS3160.5-1.0400
    1.5-3.2600
    4.0-8.0800
    RhPt10-PhSKSInconel6006.0-12.71100

    Different temperature measuring media and service conditions have an impact on the service life and temperature range of armored thermocouples, the data in the table is only recommended data.


    Accuracy for Sheath Wire Type K

    TypeClass IClass II
    AccuracyTemp.RangeAccuracyTemp.Range
    K±1.5℃-40~375℃±2.5℃-40~375℃
    ±0.4%375℃-1000℃±0.75%375℃-1000℃
    N±1.5℃-40~375℃±2.5℃-40~375℃
    ±0.4%375℃-1000℃±0.75%375℃-1000℃
    E±1.5℃-40~375℃±2.5℃-40~375℃
    ±0.4%375℃-800℃±0.75%375℃-800℃
    J±1.5℃-40~375℃±2.5℃-40~375℃
    ±0.4%375℃-800℃±0.75%375℃-800℃
    T±0.5℃-40~125℃±1.0℃-40~125℃
    ±0.4%125℃-350℃±0.75%125℃-350℃
    S0-1100℃±1.0℃0-1100℃±1.5℃

    About this product:


    Applications

    Industrial: Used in furnaces, kilns, gas turbines, and other high-temperature applications.

    HVAC: Employed in heating, ventilation, and air conditioning systems for temperature control.

    Automotive: Used in exhaust gas temperature measurements and engine monitoring.

    Food Industry: Monitors temperatures in cooking and processing environments.

    Advantages and Disadvantages

    Advantages:

    Wide temperature range.

    Simple construction and robust design.

    Fast response time and ease of use.

    Disadvantages:

    Limited accuracy compared to other sensors like RTDs.

    Non-linear output requires compensation.

    Susceptible to electromagnetic interference.

    Safety and Handling

    Thermal Shock: Avoid rapid temperature changes to prevent damage.

    Corrosive Environments: Use appropriate materials to prevent degradation.

    Handling: Handle with care to avoid mechanical damage to junctions and wires.

    Maintenance

    Regularly inspect and calibrate to ensure accurate readings.

    Clean the junction area if contamination is suspected.

    Conclusion

    Thermocouples are versatile temperature sensors suitable for a wide range of applications. Understanding their operation, types, construction, and proper handling is crucial for effective use in both industrial and laboratory settings.


    Insulation:

    Insulating materials (like ceramic or fiberglass) are often used to protect the thermocouple wires from environmental influences and prevent electrical interference.

    Sheath:

    A protective outer layer, typically made of stainless steel or Inconel, encases the thermocouple to protect it from harsh environments, mechanical damage, and chemical exposure.

    Termination Head:

    At the non-junction end, the thermocouple wires are connected to a terminal block for easy attachment to measurement instruments.

    Working Principle

    The thermocouple operates based on the Seebeck effect, which states that a voltage (thermoelectric voltage) is generated when there is a temperature difference between the hot junction (where the two metals meet) and the cold junction (reference point).

    The voltage generated is measured in millivolts and is related to the temperature difference between the junctions according to specific calibration tables (NIST tables) for each type of thermocouple.

    Applications :

    • Solid waste incinerators
    • Sintering powdered metals
    • Firing ceramic materials
    • Gas or oil fired furnaces
    • Fuel fired heat exchangers
    • Box furnaces
    • Nuclear or hydrocarbon based energy plants
    • And many more...

    Product Pictures:


    Company Information:

    A. Main Products


    K/N/E/J/T/S/R/B Type Thermocouple Temperature Probe


    B. Package

    We add heat shrink tubing and plastic film to make sure high insulated resistance.

    Except marking notes, we also have pass card and test report for every coil cable.


    K/N/E/J/T/S/R/B Type Thermocouple Temperature Probe

    C. Mi cable Production line

    We have high - quality professional products, as well as advanced product lines and equipments. All of the products comply with international quality standards and are greatly appreciated in a variety of different markets throughout the world.Along the increasing market demands, we continuously satisfy customers by updating products to improve prouduction systems, improve quality.


    Order Notice:

    1. Accurate quotation.

    2. Confirm the price, trade term, lead time, payment term etc.

    3. LEADKIN sales send the Proforma Invoice with LEADKIN seal.

    4. Customer arranges the payment for deposit and sends us bank slip.

    5. Middle Production-send photos to show the production line which you can see your products in . Confirm the estimated delivery time again.

    6. End Production-Mass production products photos.

    7. Clients make payment for balance and LEADKIN ships the goods. Inform the tracking number and check the status for clients.

    8. The order is finished perfectly when you receive the goods and get satisfied with them .

    9. Feedback to LEADKIN about Quality , Service, Market Feedback & Suggestion. And we will do better .


    Quality K/N/E/J/T/S/R/B Type Thermocouple Temperature Probe for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Ningbo Leadkin Instrument Complete Sets of Equipment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)