Sign In | Join Free | My himfr.com
Home > Mineral Insulated Thermocouple Cable >

Insulation MgO Mineral Insulated Thermocouple Cable For Accurate Temperature Measurement In Various Applications Accuracy Class I

Ningbo Leadkin Instrument Complete Sets of Equipment Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Insulation MgO Mineral Insulated Thermocouple Cable For Accurate Temperature Measurement In Various Applications Accuracy Class I from wholesalers
     
    Buy cheap Insulation MgO Mineral Insulated Thermocouple Cable For Accurate Temperature Measurement In Various Applications Accuracy Class I from wholesalers
    • Buy cheap Insulation MgO Mineral Insulated Thermocouple Cable For Accurate Temperature Measurement In Various Applications Accuracy Class I from wholesalers
    • Buy cheap Insulation MgO Mineral Insulated Thermocouple Cable For Accurate Temperature Measurement In Various Applications Accuracy Class I from wholesalers

    Insulation MgO Mineral Insulated Thermocouple Cable For Accurate Temperature Measurement In Various Applications Accuracy Class I

    Ask Lasest Price
    Brand Name : LEADKIN
    Model Number : LK-K
    Certification : ISO9001, IATF16949, CE
    Price : USD 0.5-6.8/M
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 1,000,000M/year
    Delivery Time : 2-7 working days
    • Product Details
    • Company Profile

    Insulation MgO Mineral Insulated Thermocouple Cable For Accurate Temperature Measurement In Various Applications Accuracy Class I

    Quick Details:

    Type: K/N/E/J/T/S/R/B

    Place of Origin: Zhejiang, China (Mainland)

    Accuracy: I-0.4%t, II-0.75%t, III-1.5%t

    Core number: Single / Double

    Insulator: 99.6% high purity MgO

    Certificate:ISO9001, IATF16949, CE

    Application: connecting with thermocouple and instrument machine

    Conductor material: NiCr-NiSi, NiCrSi-NiSi, NiCr-Konstantan, Fe-Konstantan, Cu-Konstantan

    Sheath material: Inconel600, 0Cr18Ni10Ti, SS304S,SS316L, SS310,SS316,GH3030, GH3039, GH747

    Sheath Dia(mm): 0.5mm to 12.7mm :φ0.5,φ1.0, φ1.5(1.6), φ2.0, φ3.0(3.2),φ4.0,φ5.0(4.8),φ6.0(6.4),φ8.0,φ12.7


    Type for Sheath Wire Type K:

    Product NameCodeTypeShaeth MaterialOutside Dia.Temperature
    NiCr-NiSi /NiCr-NiAlKKKSS304 SS3160.5-1.0400
    1.5-3.2600
    4.0-8.0800
    SS310 Inconel6000.5-1.0500
    1.5-3.2800
    4.0-6.4900
    8.0-12.71000
    NiCrSi-NiSiNKNSS304 SS3160.5-1.0400
    1.5-3.2600
    4.0-8.0800
    SS310 Inconel6000.5-1.0500
    1.5-3.2800
    4.0-6.4900
    8.0-12.71000
    NiCr-KonstantanEKESS304 SS3160.5-1.0400
    1.5-3.2600
    4.0-8.0800
    Fe-KonstantanJKJSS304 SS3160.5-1.0400
    1.5-3.2600
    4.0-8.0800
    Cu-KonstantanTKTSS304 SS3160.5-1.0400
    1.5-3.2600
    4.0-8.0800
    RhPt10-PhSKSInconel6006.0-12.71100

    Different temperature measuring media and service conditions have an impact on the service life and temperature range of armored thermocouples, the data in the table is only recommended data.


    Accuracy for Sheath Wire Type K

    TypeClass IClass II
    AccuracyTemp.RangeAccuracyTemp.Range
    K±1.5℃-40~375℃±2.5℃-40~375℃
    ±0.4%375℃-1000℃±0.75%375℃-1000℃
    N±1.5℃-40~375℃±2.5℃-40~375℃
    ±0.4%375℃-1000℃±0.75%375℃-1000℃
    E±1.5℃-40~375℃±2.5℃-40~375℃
    ±0.4%375℃-800℃±0.75%375℃-800℃
    J±1.5℃-40~375℃±2.5℃-40~375℃
    ±0.4%375℃-800℃±0.75%375℃-800℃
    T±0.5℃-40~125℃±1.0℃-40~125℃
    ±0.4%125℃-350℃±0.75%125℃-350℃
    S0-1100℃±1.0℃0-1100℃±1.5℃

    About this product:

    Construction and Installation

    Material: The choice of materials affects the thermocouple's temperature range, sensitivity, and resistance to environmental factors.

    Insulation: Thermocouples can be insulated with ceramic, glass, or plastic materials to protect against contamination and physical damage.

    Wiring: Proper wiring techniques are crucial to avoid introducing errors due to electromagnetic interference or thermal gradients.

    Calibration and Accuracy

    Calibration: Thermocouples need to be calibrated against known temperature standards to ensure accuracy. Calibration can be done using ice baths, temperature blocks, or other reference sources.

    Accuracy Factors: Errors can arise from non-linearities, reference junction temperature variations, and the quality of the thermocouple wire.

    Reference Junction Compensation.

    Cold Junction Compensation: Since the thermoelectric voltage depends on the temperature difference, the temperature of the reference junction must be known or compensated for. This is typically done using electronic circuitry that measures the reference junction temperature.

    Applications :

    • Solid waste incinerators
    • Sintering powdered metals
    • Firing ceramic materials
    • Gas or oil fired furnaces
    • Fuel fired heat exchangers
    • Box furnaces
    • Nuclear or hydrocarbon based energy plants
    • And many more...

    Product Pictures

    Insulation MgO Mineral Insulated Thermocouple Cable For Accurate Temperature Measurement In Various Applications Accuracy Class I


    Company Information:

    A. Main Products


    Insulation MgO Mineral Insulated Thermocouple Cable For Accurate Temperature Measurement In Various Applications Accuracy Class IInsulation MgO Mineral Insulated Thermocouple Cable For Accurate Temperature Measurement In Various Applications Accuracy Class IInsulation MgO Mineral Insulated Thermocouple Cable For Accurate Temperature Measurement In Various Applications Accuracy Class I


    B. Package


    We add heat shrink tubing and plastic film to make sure high insulated resistance.

    Except marking notes, we also have pass card and test report for every coil cable.


    C. Mi cable Production line

    We have high - quality professional products, as well as advanced product lines and equipments. All of the products comply with international quality standards and are greatly appreciated in a variety of different markets throughout the world.Along the increasing market demands, we continuously satisfy customers by updating products to improve prouduction systems, improve quality.


    Order Notice:

    1. Accurate quotation.

    2. Confirm the price, trade term, lead time, payment term etc.

    3. LEADKIN sales send the Proforma Invoice with LEADKIN seal.

    4. Customer arranges the payment for deposit and sends us bank slip.

    5. Middle Production-send photos to show the production line which you can see your products in . Confirm the estimated delivery time again.

    6. End Production-Mass production products photos.

    7. Clients make payment for balance and LEADKIN ships the goods. Inform the tracking number and check the status for clients.

    8. The order is finished perfectly when you receive the goods and get satisfied with them .

    9. Feedback to LEADKIN about Quality , Service, Market Feedback & Suggestion. And we will do better .


    Quality Insulation MgO Mineral Insulated Thermocouple Cable For Accurate Temperature Measurement In Various Applications Accuracy Class I for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Ningbo Leadkin Instrument Complete Sets of Equipment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)